Configuration Guide for Running Bladed Jobs with PBS and an External AD Integration

Prerequisites

External AD Server

  • Ensure the AD server is network-reachable from the Windows compute nodes.
  • Add the AD domain administrator pbsadmin. Password: <PBSADMIN_PASSWORD>. Refer to the Password Retrieval Guide. If you cannot access it, contact the corresponding customer service manager, delivery manager, or technical support personnel.
  • Make sure the AD users have both gid number and uid number configured.
  • The AD user names must match the user names on the Windows compute nodes.

External Storage

  • Ensure the external storage server is network-reachable from the Windows compute nodes.
  • Make sure the storage protocol supports both NFS and CIFS.
  • Make sure the storage supports user authentication and AD integration.

Platform Package Version

  • Platform version: 24.11bladed
  • Download location (must be this version or later): s3://fastone-artifects/fastone-package/24-11bladed/fastone-fcp-24.11bladed.228719.tgz

Procedure

Install Node Dependencies

  • Refer to PBS Node Minimal Dependency Installation.
  • Notes:
    • If a cloud Windows image is used, modify the machine SID.
    • When joining the Windows machine to the domain, set DNS to the IP address of the AD domain controller.
    • Enable remote login manually on the Windows machine and join it to the AD domain.
    • Add the pbsadmin user to the local Administrators group: net localgroup administrators "ad_domain\\pbsadmin" /add Replace ad_domain with the domain name of the AD domain controller.

Enable the Platform PBS Scheduler

  • Refer to the Knowledge Base/SOP document for enabling the PBS scheduler to run Bladed applications.

Register Nodes with the Platform

  • Note: On the Host Management page, when selecting Create Host, add the node by using the fastone user as the username.

PBS Cluster

  • Shared storage mount path:

    • Ensure the shared storage directory /fs/users is readable and writable for all users: chmod -R 777 /fs/users Replace /fs/users with the configured shared storage path.
  • Windows compute node configuration:

    • Steps:

      • Example mount script content. Log in to Windows with an AD user and perform the operation:
      @echo off
      net use Z: /d /yes # Customize the drive letter, for example Z:
      net use Z: \\fs.test.com\vol1 # Replace with your shared storage path. Ensure the path under drive Z: corresponds to the shared storage path on Linux. For example, Z:\users and /fs/users should be at the same directory level.
      • Run the script in cmd as an Administrator to mount the shared storage:
      psexec -s -h -c -f -accepteula "C:\Users\ad_user\mount-bladed.bat" # Replace with the path to your mount script
      • Note: If the drive is not Z:, update the symbolic link as well. Run the following commands in cmd as an Administrator:
      rmdir /S /Q c:\fastone  # Delete the existing symbolic link
      mklink /d c:\fastone D: # Replace D: with your own shared storage drive letter

Job Configuration

  • Configure the application and run the job:
    • Prepare a Bladed CWL document.
    • Copy the corresponding CWL file to the Fastone platform.
    • Download the latest bladed-utils.exe as described in the document.
    • Copy bladed-utils.exe to the C:\bin directory on all Windows compute nodes. Create the directory if it does not exist.
    • As described in the document, enter the file path or folder path in the input section when creating a new job on the platform, then run the job.

Common Issues

  • Job data

    • Ensure that the job data permissions on shared storage allow all users to read and write.
    • Confirm that the absolute paths in the *.in files match the shared storage path. If not, update them promptly.
    • Check whether the path to the Bladed executable in the job data matches the path in the *.in file. If not, correct it.
  • Compute node restart

    • Remount the shared storage manually.
    • PBS_MOM service stopped
      • On the head node, run pbsnodes -a to check whether the compute node status is down.
      • On the Windows node, run sc query pbs_mom to check whether the PBS_MOM service status is STOPPED.
      • Run net start PBS_MOM to start the PBS_MOM service, then run sc query pbs_mom again to verify that the service status is RUNNING.